Product Code : Emerson 18 Brand Name :Emerson Liebert
Hi Pulse 80Kva to 4800 Kva UPS
The Hipulse UPS. As captivating as it sounds is indeed a result of having a pulse on the customer needs and values, carefully designed to deliver high value investment ratio. The Hipulse UPS system has been designed with applications that must have the highest grade of availability in mind. Ranging from 80kVA to 4800kVA (parallel mode) Hipulse is a best-in-class, extremely reliable UPS, which will protect your equipment and entire facilities from voltage anomalies and outages. The proven performance & reliability, clubbed with customer delight, have made Hipulse the obvious choice across the world. From reliability to availability, from scalability to redundancy, from user-friendliness to maintainability, from parallelibility to connectivity, from investment protection to lower cost of ownership, whichever value you need, Hipulse addresses them all efficiently and effectively, better than the best in the industry.
The Hipulse is suitable for the following industries and applications
How Hipulse addresses Availability & Reliabilityâââ¬Ã¢ On-Line Double Conversion. IGBT-based PWM Inverter. Electronic circuits located away from the heat-generating devicesâââ¬Ã¢ Wide input voltage tolerance (+10/-15%). Wide input frequency tolerance (+/- 5%)âââ¬Ã¢ Automatic battery testing. Manual adjustment of bypass synchronisationâââ¬Ã¢ High overload capability of static bypass (14 times for 10 milliseconds and 10 times for 100 milliseconds)âââ¬Ã¢ Capability to handle: High crest factor loads. 100% non-linear loads. 100% unbalanced loadsâââ¬Ã¢ Redundant configurations of UPS modules How Hipulse addresses Scalabity & Redundancyâââ¬Ã¢ Hipulse can be scaled upto as high as 6 modules using any of the following configurations to achieve either scalability or redundancy of desired percentage - 1+n configuration without any kind of centralised static switch- Centralised configuration by using centralised static switch called MSS (Main Static Switch)- Some more configuration are explained further in this brochure- For some more configurations please contact our nearest sales office / representative
How Hipulse addresses User - Friendliness & User - Flexibilityâââ¬Ã¢ Provision to use any type of battery : Wet cells (Tubular or Plant̮̬), Valve Regulated Lead Acid (VRLA) / Maintenance-free and Nickel Cadmium âââ¬Ã¢ Field settability of end-cell voltage of the batteryâââ¬Ã¢ Multi-lingual LCD display How Hipulse addresses Power Communications:âââ¬Ã¢ Field protocols ModBus / Jbusâââ¬Ã¢ Netwok protocols SNMP/HTTP NIC Cardâââ¬Ã¢ Software: HiLink UPS Monitor. HiroVisor2000 + Hirolink to monitor HPAC (High Performance Air Conditioner). SiteScan + SiteLink to monitor (High Performance Air Conditioner) âââ¬Ã¢ Wall-mounted RAM (Remote Alarm Monitor) Boxâââ¬Ã¢ HiView to: Monitor power quality parameters. Provide wider gateway. Ease of trouble-shooting How Hipulse addresses Investment Protectionâââ¬Ã¢ Wide input voltage tolerance (+10/-15%)âââ¬Ã¢ Temperature-compensated battery charging (optional)âââ¬Ã¢ Automatic battery testingâââ¬Ã¢ Protection against deep discharge of batteryâââ¬Ã¢ Battery circuit breaker instead of using dc isolatorâââ¬Ã¢ Back-feed protectionâââ¬Ã¢ Short-circuit proof inverter
How Hipulse addresses Simplicity & Aestheticsâââ¬Ã¢ Simple to configure & operateâââ¬Ã¢ Simple to monitor & chooseâââ¬Ã¢ The look is aptly suited for the d̮̩cor of Server Rooms, Data Centres, Telecom Switch Rooms,Control Rooms and Medical Diagnostic Centres