| Three Phase Inverter/Automatic LIFT Backup System (ALBS) |
|
|
|
|
|
|
|
|
|
|
|
|
| TESTING SPECIFICATIONS OF THREE PHASE INVERTER/Automatic LIFT Backup System (ALBS) |
|
| DESCRIPTION |
4KVA |
5KVA |
6KVA |
8KVA |
10KVA |
12KVA |
15KVA |
20KVA |
25KVA |
30KVA |
40KVA - 70KVA |
70KVA - 100KVA |
| INVERTER MODE |
| Output Wave Form |
Sine wave |
|
| Nominal Battery Voltage |
72 VDC |
72 VDC, 96 VDC |
96 VDC, 180 VDC |
180 VDC |
180 VDC, 360 VDC |
180 VDC, 240 VDC, 360 VDC |
180 VDC, 276 VDC, 360 VDC |
276 VDC, 360 VDC |
360 VDC |
360 VDC |
360 VDC |
360 VDC |
| Output Power Factor |
0.8 |
| O/P VOLTAGE (N-L) |
230V AC ñ 2.5V AC |
| MAX. NO LOAD BATT. CURRENT |
0.9A ñ 0.2A |
| FREQUENCY |
50Hz ñ 1.0Hz |
| Total Harmonic Distortion |
<3% |
| O/P VOLTAGE (L-L) |
400 VAC ñ 2.5 VAC |
| FULL LOAD O/P CURRENT/ PHASE |
5.8A ñ 0.5A |
7.3A ñ 0.5A |
8.7A ñ 0.5A |
12A ñ 0.5A |
14A ñ 0.5A |
17A ñ 0.5A |
21.5A ñ 0.5A |
23.5A ñ 0.5A |
29.5A ñ 0.5A |
34.9A ñ 0.5A |
------- |
------- |
| LOW BATTERY INDICATION |
10.5V +/-0.2V Per Battery ( 12V Each) |
| MAINS MODE |
| INPUT VOLTAGE RANGE (N-L) |
140V AC to 280V AC |
| INPUT VOLTAGE RANGE (L-L) |
242 V AC to 484 V AC |
| MAX. CHARGING CURRENT |
10A ñ 1A |
| BOOST CHARGING VOLTAGE |
14.2V DC +/-0.2V DC Per Battery ( 12V DC Each) |
| TRICKLE CHARGING VOLTAGE |
13.7V DC +/-0.2V DC Per Battery ( 12V DC Each) |
| FOR THREE PHASE INVERTER |
| CHANGE OVER TIME (MAINS to BATTERY) |
< = 40milisec |
| CHANGE OVER TIME (BATTERY to MAINS) |
< = 10milisec |
| FOR THREE PHASE ALBS |
| CHANGE OVER TIME (MAINS to BATTERY) |
< = 30sec |
| CHANGE OVER TIME (BATTERY to MAINS) |
< = 10milisec |
| PROTECTIONS |
| PROTECTIONS |
OUTPUT NOT OK, BATTERY VOLTAGE LOW (4 AUTO RETRIES), OVER LOAD (6 AUTO RETRIES) |
| BATTERY OVER CHARGE, OVER TEMPERATURE, SHORT CIRCUIT, MAINS MCB TRIPS, |
| DISPLAYS |
| DISPLAYS |
WELCOME MESSEGE, CAPACITY, OUTPUT VOLTAGE N-L , OUTPUT FREQUENCY. LOAD PERCENTAGE |
| INPUT VOLTAGE and FREQUENCY, LOAD PERCENTAGE, BATTERY CHARGING,BATTERY VOLTAGE, ALL PROTECTIONS |
| Environmental Parameters |
| Operating Temperature |
0 Deg ââ¬â 45 Deg |
| Acoustic Noise at 1 Mtr. |
< 45 DB |
| Relative Humidity |
Max 95% non - Condensing |
| Thermal management |
Forced FAN Cooling |
| WEIGHT AND DIMENSIONS |
| With Packaging LXWXH in mm |
680x500x780 |
680x500x780 |
680x500x780 |
680x500x780 |
700x500x780 |
700x500x780 |
700x500x780 |
860x630x950 |
860x630x950 |
860x630x950 |
720x990x1450 |
---------- |
| With Out packaging LXWXH in mm |
540x340x660 |
540x340x660 |
540x340x660 |
540x340x660 |
540x340x660 |
540x340x660 |
540x340x660 |
700x450x840 |
700x450x840 |
700x450x840 |
585x800x1290 |
---------- |
| Net Weight |
72 |
78 |
88 |
92 |
92 |
107 |
107 |
173 |
217 |
205 |
353 |
---------- |
| Gross Weight |
83 |
89 |
94 |
105 |
124 |
117 |
134 |
220 |
232 |
245 |
435 |
|