TYPE OF EQUIMENT
|
TYPE OF DISTURBANCES
|
|
MOTOR FAILURE
|
LOW VOLTAGE, EXTEREME TRANSIENT SURGE VOLTAGE (LIGHTNING) PHASE LOSS (3 PHASE SYSTEMS) PHASE REVERSAL, SYSTEM FATIGUE, HARMONICS.
|
|
ELECTRICAL SYSTEM SHORTS
|
EXTREME TRANSIENT SURGE VOLTAGE (LIGHTNING) LOW VOLTAGE, IMPROPER / UNDERSIZED WIRING SYSTEM FATIGUE, HARMONICS.
|
|
PRINTED CIRCUIT BOARD FAILURE
|
TRANSIENT SURGE VOLTAGE, ELECTRICAL LINE NOISE, RMS OVER-VOLTAGE, ESD, GROUND LOOPS.
|
|
SMPS FAILURE
|
TRANSIENT SURGE VOLTAGE, ELECTRICAL LINE NOISE. EXTREME RMS OVER / UNDER VOLTAGE (+15% - 35%) OPEN NEUTRAL, IMPROPER WIRING.
|
|
LINEAR POWER SUPPLY FAILURE
|
NORMAL MODE TRANSIENT SURGE VOLTAGE / ELECTRICAL LINE NOISE, RMS OVER / UNDER VOLTAGE (+6% - 8%) HARMONICS, FREQUENCY DEVIATIONS (+/- .5%). IMPROPER WIRING
|
|
DISK DRIVE FAILURE
|
POWER LOSS, TRANSIENT SURGE / ELECTRICAL LINE NOISE, HARMONICS, IMPROPER GROUNDING / WIRING
|
|
SYSTEM LOCK-UP
|
ELECTRICAL LINE NOISE, ESD, EMI / RFI, EMF, UNDER-VOLTAGE -25 / 30%) POWER LOSS, IMPROPER GROUNDING
|
|
PROGRAM, MEMORY OR DATA ERRORS OR LOSS
|
ELECTRICAL LINE NOISE, ESD, EMI/RFI, EMF POWER LOSS. UNDER (VOLTAGE - 25 / 30%) GROUND LOOPS, IMPROPER WIRING AND BONDING
|
|
COMMUNICATION PORT FAILURE
|
IMPROPER GROUNDING AND BONDING. TRANSIENT SURGE VOLTAGE, IMPROPER WIRING, ESD.
|
|
MOVEMENT OF CRT CHARACTERS
|
IMPROPER GROUNDING AND BONDING, HARMONICS. EMF, PHASE REVEARSAL, ELECTRICAL LINE NOISE
|
|
REBOOTING OF PC
|
MOMENTARY INTERRUPTIONS
|
Technical Specification LPL277Y25-2-Q 25,000 Amps Per Phase The PowerSure Low Exposure Series are electronic grade surge protective devices designed to protect electronic equipment and microprocessor based systems from transients on sub-distribution panels, branch panels, or equipment located in low exposure locations. While every precaution has been taken to ensure accuracy and completeness in this document, Control Concepts Corporation assumes no responsibility, and disclaims all liability for damages resulting from use of this information or any errors or omissions. Nominal Operating Voltage / Phase Configuration 277/480VAC, Three Phase Wye, 4 Wire + Gnd Operating Voltage Range 277 VAC +/- 15% Operating Frequency Range 47 - 63 Hz Fault Current Rating 22kAIC ANSI/IEEE C62.41 Category A, B, & C Connection Type Conductors - 12 AWG, Form C Contacts - 18 AWG Capacity Continuous (Parallel Connection) Size 4.72 x 4.72 x 2.36 (Inches) Enclosure Rating ABS Plastic, 94V-0 Weight 5 lbs. (2.3 kgs.) Modes Of Protection L-N, L-L, N-G Indication of Suppression Status External LED, Form C contacts 50 EMI/RFI Attenuation - Normal Mode 40 dB Typical Response Time <.5 ns Operating Temperature - 40°C to 45°C Operating Humidity 0% to 95% non-condensing Warranty 5 Years Parts Maximum Continuous Operating Voltage (MCOV) Line to Neutral 575 VAC UL 1449 Ratings Line to Neutral 1800 Vpk Line to Ground 1800 Vpk Line to Line 3000 Vpk Neutral to Ground 1800 Vpk Neutral to Ground 750 Joules Maximum Surge Energy (8 x 20 s) Line to Neutral 2,250 Joules Line to Ground N/A Total 3,000 Joules Maximum Surge Current Capacity (8 x 20 s) Line to Neutral 25,000 Amps Line to Ground N/A Line to Line 25,000 Amps Neutral to Ground 25,000 Amps Total 100,000 Amps
|